Research on High Accuracy Zero Cross Time Detection Method of Power-frequency AC Signals
Abstract
Zero cross time detection method is very important in the phase measurement of powerfrequency AC signal. The detection uncertainties of most of the CMOS comparator based methods are around 200 μs, which cannot satisfy the high accuracy phase measurement. We proposed a new detecting method with higher accuracy by processing the sampled sequence of the under-test signal to estimate the relative frequency and phase sequentially. We implemented this method on a lowcostSoPC (system on a programmable chip), and used oscillation multiplication technique to improve the detection uncertainty to 1μs. We designed a test bench and tested the implemented detector and the results illustrated the performance of this method.
Keywords
Zero cross, Phase, Power-frequency, Parameter estimation
DOI
10.12783/dtcse/csma2017/17339
10.12783/dtcse/csma2017/17339
Refbacks